Location Recorder Model PD606
Chapter 8: MENU mode/SYS SETUP menu
6)
Press the [EXIT] key repeatedly until you exit the MENU mode.
The “Digital out” menu item selects the format (AES/EBU or S/P DIF) of the digital signal which
is output from the [DIGITAL I/O] connector.
IEC 60958 Part3 (AES/EBU) format digital signal is output.
AES/EBU
S/P DIF
IEC 60958 Part2 (S/P DIF) format digital signal is output.
Digital output signal format selection [Digital out]
You can select from among “AES/EBU” and “S/P DIF” (the default is “AES/EBU”).
Options
1)
While the unit is stopped, press the [SHIFT] key to light the SHIFT indicator, followed by the
[ENTER/YES] key.
2)
While “SYS SETUP” is highlighted, press the [ENTER/YES] key.
The display now shows the SYS SETUP menu screen.
5)
Press the [EXIT] key repeatedly until you exit the MENU mode.
4)
Use the [MENU] dial to select the desired option and press the [ENTER/YES] key to confirm
your setting.
3)
Use the [MENU] dial to select the “Digital out” menu item and press the [ENTER/YES] key.
The current setting starts flashing and you can now select the desired option.
When you set the "ST-LR" source to "Digital", you cannot record the stereo
buss signals to the ST tracks.
The display examples below show when channel pairs are set to "DIGITAL"
on the record source select screen. The digital signal format (AES/EBU or S/P DIF) is
automatically detected. If a valid digital signal is not available, the record source
automatically switches to the analog signals.
When CH1-2 and CH3-4
are set to "DIGITAL"
When all channels are
set to "DIGITAL"
Flashing