beautypg.com

Poe event log messages, Poe event log messages -17 – HP 2600 User Manual

Page 223

background image

PoE Event Log Messages

PoE operation generates these Event Log messages. You can also configure
the switch to send these messages to a configured debug destination (terminal
device or SyslogD server.

I 1MM/DD/YY HH:MM:SS chassis:

Message header, with severity, date, system time, and system
module type. For more information on Event Log operation, refer
to the “Troubleshooting” appendix in the Management and
Configuration Guide for your switch.

Ext Power Supply connected, supplying

< actual-power >

W of

< avail-power >

W max.

The switch detected an EPS (External Power Supply) and began
receiving the wattage indicated by

< actual-power >. The < avail-

power > field indicates the maximum power (wattage) the
detected EPS is capable of delivering

Ext Power Supply disconnected

The switch has lost contact with an external power supply.

POE usage is below configured threshold of

<1 - 99>

%

< slot-# >

POE usage is below configured threshold of

<1-99>

%

Indicates that POE usage in the switch or indicated slot (if the
switch includes module slots) has decreased below the threshold
specified by the last execution of the global

power threshold <1 - 99>

command. This message occurs if, after the last reboot, the PoE
demand on the switch exceeded the power threshold and then later
dropped below the threshold value.

Port

< port-# >

applying power to PD.

A PoE device is connected to the port and receiving power.

Port

< port-# >

PD detected.

The switch has detected a PoE device connected to the port.

This manual is related to the following products: