Note:

• Less than 6 positions can be measured, but it is

recommended to measure in all 6 positions in order
to obtain the best results.

• The time needed to complete calculations depends

on the number of connected speakers and measured
listening positions. The more speakers and listening
positions, the more time is needed.

10.

Checking Measurement Results

When calculations for the measurement results

end, a screen appears for confirming the
calculation results.

C H E C K R E S U L T

S P E A K E R S C O N F I G

S P E A K E R S S I Z E
D I S T A N C E
C H A N N E L L E V E L
C R O S S O V E R F R E Q

S T O R E

E X I T

Select items to check with the

3

/

4

cursor

buttons and press the ENTER button to enter
them.

Note:

To check equalizer (MultEQ) parameters, see page
38.

[Example] Confi rmation screen for speaker detection

S P E A K E R C O N F I G
C H E C K ! ! S P E A K E R
F R O N T : Y E S
C E N T E R : N O N
F R O N T R : Y E S
S U R R . R : Y E S
S U R R . B R : N O N
S U R R . B L : N O N
S U R R . L : Y E S
S U B W : Y E S

R E T U R N

N E X T

[Example] Confi rmation screen for the distance from

speakers to the listening position

D I S T A N C E
U N I T :

f t

F R O N T L : 3 0 . 0 0 f t
C E N T E R : 1 9 . 3 3 f t
F R O N T R : 2 9 . 6 6 f t
S U R R . R : 2 1 . 5 0 f t
S U R R . B R : 1 2 . 3 3 f t
S U R R . B L : 1 1 . 6 6 f t
S U R R . L : 1 6 . 3 3 f t
S U B W : 1 2 . 5 0 f t

R E T U R N N E X T

* The units can be changed by moving the cursor to

[ft] of UNIT and pressing

1

/

2

the cursor buttons.

Each time a

1

/

2

cursor button is pressed, the units

alternate between [ft] (feet) and [m] (meters).

Note:

Pressing “EXIT” prior to pressing “STORE” erases all
measurement results and calculation results, therefore
operate the remote controller with care.

When storing operations end, the following OSD
appears on the display.

2 . S P K R S E T U P

A U T O S E T U P

M A N U A L S E T U P

T H X A U D I O S E T U P

R E T U R N

E X I T

Notes:

• Do not turn the power to the unit off while storing

parameters in memory. This may erase all data in the
unit’s memory and may damage the unit.

• Please set any THX Certifi ed speakers manually to

“Small” and the crossover “80 Hz” after Auto setup
operation.

[Example] Confi rmation screen for speaker size and

crossover frequency

S P E A K E R S I Z E

F R O N T L : A U T O
C E N T E R : A U T O
F R O N T R : A U T O
S U R R . R : A U T O
S U R R . B R : A U T O
S U R R . B L : A U T O
S U R R . L : A U T O

R E T U R N

N E X T

C R O S S O V E R F R E Q

F R O N T : A U T O
C E N T E R : A U T O
S U R R : A U T O
S U R R . B : A U T O

R E T U R N

* AUTO is displayed to indicate that the speaker size

and crossover frequency results were automatically
measured.

11.

Storing Measurement Results in Memory

Once finished confirming the measurement

results, select “RETURN” with the

3

/

4

cursor

buttons and press the ENTER button to display
the CHECK RESULT screen.

C H A N N E L L E V E L

F R O N T L : 0 . 0 d B
C E N T E R : - 6 . 5 d B
F R O N T R : - 1 . 5 d B
S U R R . R : + 1 . 0 d B
S U R R . B R : + 9 . 5 d B
S U R R . B L : + 1 2 . 0 d B
S U R R . L : - 2 . 5 d B
S U B W : - 1 2 . 5 d B

R E T U R N

N E X T

C H E C K R E S U L T

S P E A K E R S C O N F I G
S P E A K E R S S I Z E
D I S T A N C E
C H A N N E L L E V E L
C R O S S O V E R F R E Q

S T O R E

E X I T

Place the cursor on “STORE” and press

the ENTER button to store all parameters
including the equalizer parameters in memory.
If not wanting to store the calculation results in
memory, place the cursor on “EXIT” and press
the ENTER button.

AV8003_U_Eng.indb 28