20ma current loop), Rs232) – Industrial Data Systems IDS DT200 User Manual
Page 54

DT 200 Users Manual version 1.E
50
DB 25 PIN MALE
(20ma Current Loop)
TB5
Serial Com Port 2
+5V
CL2 TX
1 
7 
22
CL+ 
CL- 
DT210 / IDS550 / IDS710
8
Desktop Models DB 9 Female
(RS232)
COM3
Serial Com Port 3
RXD
TXD
GND
2 
3 
5 
 TXD 
 RXD 
Scale Indicator Port
GND
Stainless Steel Models Terminal Block TB7
(RS232)
COM3
Serial Com Port 3
TXD
RXD
GND
2 
3 
5 
 RXD 
 TXD 
Scale Indicator Port
GND