Built In Application Programs
14
REBUILD ID MEMORY: Press the ENTER key when the display prompts, “rebuiLd”.
The display then prompts “id”. Enter the numeric 0 then press ENTER to rebuild ID
memory.
COUNT UNUSED ID’S: Press the ENTER key when the display prompts “Count”.
The display prompts “FrExxx” where xxx is the number of unused ID records in
memory.
Set Beginning Sequence Number
Use the numeric keypad to enter number 9. The display prompts "reg 9" for 1 second and
then displays the current value. Press the CLEAR key if no change is to be made, or
enter a new value and then press the ENTER key. The next sequence number printed
will be the entered value +1.
Options
• Print key: Set parameter 52 = 4 (execute user function 4) to enable the print key to
print the weight on the scale. The print data is sent to Serial Communications Port 1.
If units other than lb are used, change print label 85 to the correct units. (This option
is not available for printers that use the parallel output port).
• Unit’s key: Set parameter 53 = 127 (execute Units function) if weighing is dual units
is required.
Notes
• The ID file maintenance functions are password level 1 protected. If a password has
been configured (function 64) the operator will be prompted for the password before
the file maintenance menu is displayed.
• ID memory is cleared to zero at power up unless CFG parameter 41 (battery back up
enable) is set to 1.