Industrial Data Systems IDS DT200 User Manual
Page 21

DT 200 Users Manual version 1.E
Built In Application Programs
17
# 6 ID, Tare, and Total
This program uses the ID memory to store tare weights and totals.
Enter ID Tare Data
Press the
F1 key. The display prompts "id". Enter up to 8 digits for ID and then press
the ENTER key. The display prompts “tArE”. Enter the tare weight.
Recall ID and Tare
Press the
F2 key. The display prompts "id". Enter up to 8 digits for the weigh-out ID
and then press the ENTER key. The indicator recalls the ID from memory and copies the
ID tare to the tare register.
Print and Total ID
Recall an ID and then press the Print key. The ID number, Gross, Tare, and Net are
printed. The Net weight is added to the ID’s totals register.
Print ID’s, Display ID’s, Clear Totals, Erase ID’s
Entering ID 0 accesses the ID maintenance functions. Press the F1 (or F2) key, press the
numeric 0 key, and then press the ENTER key. The display prompts "rePort". Press the
UNITS (
↓) key or the PRINT (↑) key to scroll through the ID file maintenance menu.
REPORT: Press the ENTER key when the display prompts "rePort". The display then
prompts "id". Enter an ID number to be printed or enter the numeric 0 to print all ID's.
DISPLAY ID’s: Press the ENTER key when the display prompts “diSPLA”. The
display then prompts “id”. Enter an ID number to display the data in its registers, or
enter 0 to scan ID memory.
CLEAR TOTALS: Press the ENTER key when "CLEAr" is displayed. The display
prompts "id". Enter an ID number to clear or enter the numeric 0 to clear all ID totals.
ERASE ID'S: Press the ENTER key when the display prompts "ErASE". The display
then prompts "id". Enter an ID to be erased or enter the numeric 0 to erase all ID's.
REBUILD ID MEMORY: Press the ENTER key when the display prompts, “rebuiLd”.
The display then prompts “id”. Enter the numeric 0 then press ENTER to rebuild ID
memory.
COUNT UNUSED ID’S: Press the ENTER key when the display prompts “Count”.
The display prompts “FrExxx” where xxx is the number of unused ID records in
memory.
Set Beginning Sequence Number
Use the numeric keypad to enter number 1. The display prompts "reg 1" for 1 second and
then displays the current value. Press the CLEAR key if no change is to be made, or
enter a new value and then press the ENTER key. The next sequence number printed
will be the entered value +1.