Built In Application Programs

15

# 4 Axle Weigh – Short Scale

Automatically weigh multiple axles (or containers), print each axle weight, and print axle

total.

Installation

Connect the Red light / Green light relays.

Green light = TTL out 1

TB4 pin 1

Red light =

TTL out 2

TB4 pin 2

Setup Parameters

Configure the following parameters:

Parameter 43

Trip level weight. Determines when an axle is on the scale.

Parameter 74, 1

Red light turn delay timer. This provides a delay time before the

Red light output is turned on.

Parameter 74, 2

Green light turn delay timer. The amount of delay time before the

Green light is turned on.

Parameter 74, 3

Finish timer. Amount of time to wait before automatically

activating the finish function.

Operators Functions

The unit is capable of operating unattended, with no operator intervention. The indicator

determines when an axle is on the scale by the increase (or decrease) of weight on the

scale.

A finish timer (parameter 74-3) determines when to complete a weigh cycle (print total

and wait for empty scale).

Press the

F1 key to manually finish a weigh cycle before finish timer has timed out.

Press the

F2 key to abort weigh cycle.