3. Installation

3-5

Festo P.BE-MTR-DCI-DN-EN en 1209a

The plug connectors of the following Festo cables have been
designed so that, when inserted and screwed tight, or if fitted
with protective covers, the connections on the MTR-DCI will
comply with protection class IP54.

Caution
Long lines reduce immunity to interference (EMC).

Do not exceed the specified maximum cable lengths.

Connection

Cable

Designation

Length [m]

Serial interface

Programming cable

KDI-MC-M8-SUB-9-2,5

2.5 (max. 2.5)

Homing Switch

Connecting cable

KM8-M8-GSGD-...

0.5 / 1 / 2 / 5

Fieldbus interface

Field bus plug for M12
adapter

FBA-CO-SUB-9-M12

Voltage supply

Power supply cable

KPWR-MC-1-SUB-9HC-...

2.5 / 5 / 10
(max. 10)

Tab. 3/2: Overview of cables (accessories)

To maintain the IP protection class:

Seal unused M8 connections with ISK-M8 protective caps
(accessories).

Hand-tighten the union nuts/locking screws of the plugs:

Observe the permitted tightening torques specified in the
documentation for the cables and connectors used.