beautypg.com

Festo Электромотор MTR-DCI User Manual

Page 261

background image

B. Reference – Festo DeviceNet and FHPP

B-39

Festo P.BE-MTR-DCI-DN-EN en 1209a

Gear Ratio

FHPP

1002

1, 2

Array

uint32

rw

Description

Relationship of the internal motor rotation to the external rotation of the
MTR-DCI drive shaft. The values are permanently set for each different internal
gearing (see rating plate on the MTR-DCI).
Gear ratio = motor revolutions / spindle revolutions

Motor Revolutions 1002

1

uint32

rw

Internal motor revolutions (Gear ratio – numerator)
Gearing G7:

Fixed: 27 (0x1B)

Gearing G14:

Fixed: 3969 (0xF81)

Gearing G22:

Fixed: 1710 (0x6AE)

Shaft Revolutions 1002

2

uint32

rw

External revolutions of the drive shaft of the MTR-DCI
(gear ratio – denominator).
Gearing G7:

Fixed: 4 (0x04)

Gearing G14:

Fixed: 289 (0x121)

Gearing G22:

Fixed: 77 (0x4D)

CI

6091h

01h, 02h

Array

uint32

rw

DeviceNet

6Bh

01h

04h, 05h

uint32

ro

Feed Constant

FHPP

1003

1, 2

Array

uint32

rw

Description

The feed constant specifies the distance (=feed) that the slide moves when the
drive shaft (spindle) of the linear axis performs one revolution (feed constant =
feed / spindle revolution).

Feed 1003

1

uint32

rw

Specification of feed (feed constant - counter) in [μm].
When known axis types are selected on the control panel or in FCT, the value
is entered automatically.

Shaft Revolutions 1003

2

uint32

rw

Feed constant – denominator.
Fixed: 1 (0x01)

CI

6092h

01h, 02h

Array

uint32

rw

DeviceNet

6Bh

01h

06h, 07h

uint32

rw