Commissioning 5-43 – Festo Электромотор MTR-DCI User Manual
Page 141
5. Commissioning
5-43
Festo P.BE-MTR-DCI-DN-EN en 1209a
1. Record selection: establish “ready to operate”
status
1.1
Basic status of the drive when the supply voltage is
switched on.
} Step 1.2 or 1.3
1.2
Disable device control by FCT/HMI.
Optionally, the takeover of device control by FCT/HMI
can be blocked with CCON.B5 = 1 (LOCK).
} Step 1.3
1.3
Enable drive (record selection)
} Homing: example 4, Tab. 5/12.
Step/
Description
O data
I data
Byte
B7 B6 B5 B4 B3 B2 B1 B0 Byte
B7 B6 B5 B4 B3 B2 B1 B0
1.1 Basic status
(HMI device control =
off )
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
0
0
0
0
x
0
0
SCON
0
0
0
1
0
0
0
0
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
0
0
SPOS
0
0
0
0
0
1
0
0
1.2 Disable device
control by FCT/HMI
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
x
x
1
0
x
x
x
x
SCON
x
x
0
x
x
x
x
x
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
x
x
x
x
x
x
x
SPOS
x
x
x
x
x
x
x
x
1.3 Enable drive,
enable operation
(Record Select)
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
0
x
0
0
x
1
1
SCON
0
0
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
0
1
SPOS
0
0
0
0
0
1
0
1
0: 0 signal
1: 1 signal;
x: not relevant (any);
F: Edge positive
Tab. 5/9: I/O data “Record selection: establish ready to operate status”
If there are faults after switching on or after setting CCON.B0
(ENABLE):
} Fault handling: see example 3, Tab. 5/11.