beautypg.com

A.1 technical data – Festo Электромотор MTR-DCI User Manual

Page 207

background image

A. Technical appendix

A-3

Festo P.BE-MTR-DCI-DN-EN en 1209a

A.1

Technical data

General information

Protection class to EN 60529

IP54 (plug connectors plugged in or fitted with protective
cap)

Relative humidity

0 to 95 %, non-condensing

Temperature range

Operation: 0 ... +50 °C
Storage/transport: -25 ... +60 °C

Vibration and shock

Vibration

tested in accordance with DIN/IEC 68/EN 60068 parts 2-6;
0.15 mm path at 10 ... 58 Hz;
2 g acceleration at 58 ... 150 Hz

Shock

tested in accordance with DIN/IEC 68/EN 60068
parts 2-27;
±15 g at 11 ms duration;
5 shocks in each direction

Shock resistance

Tested in accordance with DIN/IEC 68/EN 60068
parts 2-29,
±15 g at 6 ms duration;
1000 shocks in each direction

Protection against electric shock

1)

Protection by a PELV power unit against direct and indirect
contact as per IEC/DIN EN 60204-1
(Protected Extra-Low Voltage)

Electromagnetic compatibility (EMC)

2)

See declaration of conformity (www.festo.com)

Gearing type

Planetary gearing

Encoder (with 4x evaluation)

MTR-DCI-32: 300 x4 —> 1200 Increments/Revolution
MTR-DCI-42, 52, 62: 500 x4 —> 2000 Increments/Revol-
ution

Temperature monitoring

Warning message at 70 °C < T < 80 °C
Shut-down at temperature ≥ 80 °C

Display resolution

128 x 64 pixels

1)

The device is intended for industrial use.

2)

The maximum permitted I/O signal cable length is 30 metres.