A.1 technical data – Festo Электромотор MTR-DCI User Manual
Page 207
A. Technical appendix
A-3
Festo P.BE-MTR-DCI-DN-EN en 1209a
A.1
Technical data
General information
Protection class to EN 60529
IP54 (plug connectors plugged in or fitted with protective
cap)
Relative humidity
0 to 95 %, non-condensing
Temperature range
Operation: 0 ... +50 °C
Storage/transport: -25 ... +60 °C
Vibration and shock
–
Vibration
tested in accordance with DIN/IEC 68/EN 60068 parts 2-6;
0.15 mm path at 10 ... 58 Hz;
2 g acceleration at 58 ... 150 Hz
–
Shock
tested in accordance with DIN/IEC 68/EN 60068
parts 2-27;
±15 g at 11 ms duration;
5 shocks in each direction
–
Shock resistance
Tested in accordance with DIN/IEC 68/EN 60068
parts 2-29,
±15 g at 6 ms duration;
1000 shocks in each direction
Protection against electric shock
1)
Protection by a PELV power unit against direct and indirect
contact as per IEC/DIN EN 60204-1
(Protected Extra-Low Voltage)
Electromagnetic compatibility (EMC)
2)
See declaration of conformity (www.festo.com)
Gearing type
Planetary gearing
Encoder (with 4x evaluation)
MTR-DCI-32: 300 x4 —> 1200 Increments/Revolution
MTR-DCI-42, 52, 62: 500 x4 —> 2000 Increments/Revol-
ution
Temperature monitoring
Warning message at 70 °C < T < 80 °C
Shut-down at temperature ≥ 80 °C
Display resolution
128 x 64 pixels
1)
The device is intended for industrial use.
2)
The maximum permitted I/O signal cable length is 30 metres.