beautypg.com

A.2 accessories – Festo Электромотор MTR-DCI User Manual

Page 210

background image

A. Technical appendix

A-6

Festo P.BE-MTR-DCI-DN-EN en 1209a

Fieldbus Data

Design
– Physical layer
– Data link layer

as per ISO 11898 (corresponding to DS 102)
as per CAN specification 2.0

DeviceNet Specification

as per IEC62026 and EN50325
Predefined connection set: Group 2 slave only

DeviceNet device type

Communication Adapter (0x12)

Manufacturer ID

Festo Corporation 26 (0x1A)

Address area (MAC ID)

0 ... 63

Bus termination resistor

121 Ω, 0.25W, external

Transmission rate

125, 250, 500 kbit/s

Interface

Plug

Electrical isolation

Integrated bus termination

D-Sub, 9-pin
yes
no

Cable type

dependent on cable length and fieldbus bit rate,
see controller manual

A.2

Accessories

Connection

Accessories

Designation

Length [m]

Voltage supply

Power supply cable

KPWR-MC-1-SUB-9HC-...

2.5 / 5 / 10

Serial interface

Programming cable

KDI-MC-M8-SUB-9-...

2.5

Homing Switch

Switch, magnetic
Switch, inductive

SMT-8M-...-M8D
SIEN-...-M8B-...

Connecting cable with
screw-type lock

KM8-M8-GSGD....

0.5 / 1 / 2 / 5

Fieldbus connection
including logic voltage
power supply

Fieldbus adapter (IP54)

FBA-CO-SUB-9-M12