7 examples of i/o data, Ensuring device control, Commissioning 5-42 – Festo Электромотор MTR-DCI User Manual
Page 140: Step/ description o data i data
5. Commissioning
5-42
Festo P.BE-MTR-DCI-DN-EN en 1209a
5.5.7
Examples of I/O data
The following pages provide typical examples of the I/O data
according to the FHPP standard:
1. Record selection: establish “ready to operate” status
2. Direct task: establish “ready to operate” status
3. Fault handling
4. Homing
5. Record selection: Positioning mode
6. Direct task: Positioning mode
7. Direct task: Force mode
A description of the MTR-DCI's finite state machine can be
found in section 5.8.
Ensuring device control
Step/
Description
O data
I data
Byte
B7 B6 B5 B4 B3 B2 B1 B0 Byte
B7 B6 B5 B4 B3 B2 B1 B0
0.1 HMI device con-
trol = on
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
0
0
0
0
x
0
0
SCON
0
0
1
1
0
0
0
0
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
0
0
SPOS
0
0
0
0
0
1
0
0
0: 0 signal
1: 1 signal;
x: not relevant (any);
F: Edge positive
Tab. 5/8: I/O data: “Device control active”
Device control via the control panel or the Festo Configuration
Tool has been activated. To control the MTR-DCI via the
DeviceNet interface, device control by FCT/HMI must first
be deactivated.