Serial transmission mode, Table 11-4 modbus transmission modes – Lantronix XPORT PROTM 900-560 User Manual
Page 100

11: Modbus
XPort Pro User Guide
100
Serial Transmission Mode
Evolution products can be set up to communicate on standard Modbus networks using either RTU 
or ASCII. Users select the desired mode and serial port communication parameters (baud rate, 
parity mode, etc) during the line configuration.
Table 11-4
Modbus Transmission Modes
The Modbus web pages allow you to check Modbus status and make configuration changes. This 
chapter contains the following sections:
Force 
Multiple 
Coil
0x0F
Echo query
Echo query
Echo query
Echo 
query
N/A
N/A
N/A
Preset 
Multiple 
Registers
0x10
Echo query
Echo query
Echo query
Echo 
query
N/A
N/A
N/A
Read/
Write 4X 
Registers
0x17
0x02-0x06
(Quantity of 
Read) * 2
Max [6]..
0x00, 0x0Y
0x00 ,0x0Y
0x00, 0x0Y
Y = 0 or 1
RTU
ASCII
Address: 8 bits (0 to 247 decimal, 0 is used 
for broadcast)
Function: 8 bits (1 to 255, 0 is not valid)
Data: N X 8 bits (N=0 to 252 bytes)
CRC Check: 16 bits
Address: 2 CHARS
Function: 2 CHARS
Data: N CHARS (N=0 to 252 CHARS)
LRC Check: 2 CHARS
Name
Number
Byte 
Count
Data [0]
Data [1]
Data 
[2]
Data [3]
Data
[4]
Data [5]