Henny Penny PFE-592 User Manual
Page 40
Model 590/592
1. Raise the lid and remove the retention ring from one end of
the lid pin.
2. Slide the lid pin from unit.
3. Lift the lid from unit.
The lid weighs 80 lbs (36 kg). Take care when lifting lid
to prevent personal injury.
4. Using a 3/8” socket, remove the nuts securing the rear
shroud and remove shroud.
5. Using a Phillip’s-head screwdriver, remove the screws
securing the top cap and remove top cap.
6. Remove the bolts securing the nylatron strips to the weight
assembly and remove strips from weight assembly.
7. Using a Phillip’s-head screwdriver, remove the screws
securing the front shroud.
8. Unfasten the exhaust hose from the hose clamp.
2-24
1103
2-23. NYLATRON STRIPS
REPLACEMENT
This manual is related to the following products: