background image

Model 590/592

1. Raise the lid and remove the retention ring from one end of

the lid pin.

2. Slide the lid pin from unit.

3. Lift the lid from unit.

The lid weighs 80 lbs (36 kg). Take care when lifting lid

to prevent personal injury.

4. Using a 3/8” socket, remove the nuts securing the rear

shroud and remove shroud.

5. Using a Phillip’s-head screwdriver, remove the screws

securing the top cap and remove top cap.

6. Remove the bolts securing the nylatron strips to the weight

assembly and remove strips from weight assembly.

7. Using a Phillip’s-head screwdriver, remove the screws

securing the front shroud.

8. Unfasten the exhaust hose from the hose clamp.

2-24

1103

2-23. NYLATRON STRIPS
REPLACEMENT