Model 590/592
Problem
Cause
Correction
HEATING OF SHORTENING SECTION (Continued)
Heating of shortening
• Low or improper voltage
• Use a meter and check the
too slow
receptacle against data plate
• Weak or burnt out element(s)
• Check heating element(s) per
Heating Elements Section
• Points in contactor bad
• Check contactor per Heating
Contactors Section
• Wire(s) loose
• Tighten
• Burnt or charred wire
• Replace wire and clean
connection
connectors
Shortening
• Programming wrong
• Check temperature setting
overheating
in the program mode
• Faulty PC board
• Remove and replace control
panel
• Faulty temperature probe
• Remove and replace temperature
probe
• Check contactor for not
• Check faulty contactor per
opening
Heating Contactors Section
1103