Henny Penny PFE-592 User Manual
Page 12

Model 590/592
•
Blown fuse or tripped
•
Reset breaker or replace fuse
circuit breaker at supply
box or control panel
•
Blown fuse in PC board
•
Replace glass fuse in board
•
Faulty POWER/PUMP switch.
•
Check POWER/PUMP switch
per maintenance section on
the POWER/PUMP switch
•
Faulty cord and plug
•
Check cord and plug
• Check power at receptacle
•
Faulty drain switch
•
Check drain switch per
maintenance section on
drain switches
•
Faulty PC Board
•
Remove and replace control
panel
•
Faulty high limit control switch
•
Check high limit control
switch per maintenance
section on the high limit
•
Drain valve open
•
Close drain valve
•
Possible faulty temperature probe
•
Replace temperature probe
•
Faulty contactor
•
Check contactor per maintenance
section on contactors
1-8
1002
Problem Cause
Correction
HEATING OF SHORTENING SECTION