Henny Penny PFE-592 User Manual
Page 10

Model 590/592
Problem
Cause
Correction
POWER SECTION
With switch in
•
Open circuit
•
Check to see that unit is
POWER position,
plugged in
the fryer is com-
•
Check the breaker or fuse
pletely inoperative
at supply box
(NO POWER)
•
Check voltage at wall
receptacle
•
Check MAIN POWER
switch; replace if defective
•
Check cord and plug
• Check 15 amp fuses
Pressure will not
•
Exhaust line from solenoid
•
Turn unit off and allow
exhaust at end of
valve to exhaust tank
fryer to cool to release
cook cycle
clogged
pressure from frypot;
clean all pressure lines,
exhaust stacks, and exhaust
tank
•
Solenoid valve clogged
•
Check and clean solenoid
valve per maintenance
section on solenoid valve
Operating
•
Deadweight clogged
•
Turn unit off and allow
pressure too high
fryer to cool to release
pressure from frypot;
remove dead weight and
clean
•
Exhaust line to stack clogged
•
Clean exhaust line to stack
1-6
1103
DO NOT OPERATE UNIT IF HIGH PRESSURE CONDITIONS EXIST; SEVERE INJURIES
AND BURNS WILL RESULT. PLACE THE POWER/PUMP SWITCH IN THE OFF POSI-
TION IMMEDIATELY. RELEASE THE PRESSURE BY ALLOWING UNIT TO COOL. THE
PRESSURE WILL THEN DROP. DO NOT RESUME USE OF UNIT UNTIL CAUSE OF HIGH
PRESSURE HAS BEEN FOUND AND CORRECTED.
PRESSURE SECTION