11. Pull excess capillary line from pot and tighten nut into

frypot wall.


Be sure capillary bulb of high limit is positioned so it does

not interfere with carrier or get damaged when cleaning

frypot.

12. With excess capillary line pulled out, tighten smaller nut.

13. Replace inner and front panels.

14. Ref ll with shortening.

There are two fuse holders on each model of the electric fryers.

To check or change fuse, unscrew black fuse holder cap.

To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

Checking Procedure for Fuse Holders

CONTROL PANEL FUSES 3 Phase

Remove the control panel and pull the wires from the fuse

holder terminals. Using a multimeter or continuity light, check

across the terminals. The circuit should be closed. If not, re-

place the fuse (HP# EF02-007) or fuse holder (HP# EF02-006).