beautypg.com

Henny Penny PFE-592 User Manual

Page 34

background image

Model 590/592

To avoid electrical shock, make connections before
applying power, take reading, and remove power

before removing meter leads. The following checks
are performed with the wall circuit breaker closed and
the main power switch in the ON position.

4. With power reapplied and in a heat-up mode, check the

power going to both contactor coils. This is to be sure

power is going to the contactors.

If no voltage is found going into the primary contactor coil,

check wiring, high limit, and drain switch. If no voltage at heat

contactor coil, check wiring and connections at PC board.

Replacement

If either contactor proves defective, replace as follows:

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

1. Label and remove only those wires directly connected to

the contactor being replaced.

Hint: Removing the left side panel may be helpful in

replacing the heat contactor.

2. Remove the mounting screws on the base plate of the

primary contactor and remove contactor. Proceed to step 5.

3. Remove the screws securing the mercury contactor bracket

to the mounting plate and remove bracket and contactor.

4. Remove the screws securing the contactor to the bracket

and remove contactor from bracket.

5. Install new contactor in reverse order.

6. Install control panel and reconnect power to the fryer and

test for proper operation.

2-18

1103

2-19. CONTACTORS
(Continued)