beautypg.com

Heat & Glo Fireplace 6000TRS-CE User Manual

Page 43

background image

Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13

43

Symptom

Possible Cause

Corrective Action

5. The pilot and

main burner

extinguish while

in operation.

a. No LP in the tank

Check the LP (propane) tank. Refill the

fuel tank.

b. Inner flue pipe leaking

exhaust gases back into

the system

Check for gas leaks.

c. Horizontal flue improperly

pitched

The horizontal flue cap should slope down

only enough to prevent any water from

entering the unit. The maximum downward

slope is 0.6 cm.

d. Glass too loose and

air tight packet leaks in

corners after usage

Tighten the corner.

e. Bad thermopile or

thermocouple

Replace if necessary.

f. Improper flue cap

installation

Check for proper installation and freedom

from debris or blockage.

6. Glass soots.

a. Flame impingement

Adjust the log set so that the flame does

not excessively impinge on it.

b. Improper venturi setting

Adjust the air shutter at the base of the

burner.

c. Debris around venturi

Inspect the opening at the base of the

burner. NO MATERIAL SHOULD BE

PLACED IN THIS OPENING.

7. Flame burns

blue and lifts off

burner.

a. Insufficient oxygen being

supplied

Ensure that the flue cap is installed properly

and free of debris. Ensure that the flue

system joints are tight and have no leaks.
Ensure that no debris has been placed in

the area at the base of, or in the area of,

the air holes in the center of the base pan

beneath the burner.
Ensure that the glass is tightened properly

on the unit, particularly on top corners.