Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13

25

!

Figure 22. venting through the wall

• The heat shield sections will overlap to match the wall

thickness (depth). The small leg in the shield rests on

top of the flue to properly space it from the pipe section

(see Figure 22).

• The termination kit should pass through the wall fire-

stops from the exterior of the building.

• Adjust the termination cap to its final exterior position

on the building and interlock the flue sections.

EXTERIOR

INTERIOR

Interior

Wall Shield

Inner Flue

Rear Vent

Heat Shield

3.8 cm min.

overlap

Outer Flue

3.8 cm min.

Overlap

• Use a high-temperature sealant gasket to seal between

the pipe and exterior firestop.

wARNING: THE TERMINATION CAP MUST

BE POSITIONED SO THAT THE ARROw IS

POINTING UP.