beautypg.com

B. installing flue components – Heat & Glo Fireplace 6000TRS-CE User Manual

Page 20

background image

Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13

20

wARNING: THE REAR FLUE COLLAR SEAL

CAP MUST REMAIN ATTACHED TO THE REAR

FLUE COLLARS IF THE FLUE SYSTEM IS AT-

TACHED TO THE TOP STARTING COLLARS.

SEE FIGURE 15.

Figure 15

B. Installing Flue Components

After determining which set of starting collars will be used

(top or rear), follow venting instructions accordingly.
venting Out the Rear Flue
Remove the installed rear seal cap from the rear starting

collars by cutting the strap at each end (See Figure 15).

Follow the flue configuration tables accordingly.
Remove the 12.7 cm diameter heat shield from the 1.27 cm

diameter collar by sliding it out. Remove insulation piece.

wARNING: FAILURE TO REMOvE INSULA-

TION IN THE SET OF COLLARS YOU ARE

USING COULD CAUSE A FIRE.

wARNING: YOU MUST LEAvE THE INSULA-

TION IN PLACE IN THE SET OF COLLARS YOU

ARE NOT USING.

!

!

!

!

WARNING: THE TOP HEAT SHIELD (INSIDE

THE FIREBOx) MUST REMAIN ATTACHED IF

THE FLUE SYSTEM IS ATTACHED TO THE

REAR STARTING COLLARS. SEE FIGURE 15.

venting Out the Top Flue
Remove the top flue collar seal cap by cutting the strap on

each end. Remove both pieces of insulation inside the top

two starting collars (see Figure 15).
Remove the 10.2 cm diameter heat shield from the 10.2

cm diameter collar by sliding it out.
You have to take the glass off again for positioning the

logs when the unit is finally installed in place and finished

around it. Reinstall the glass door. Attach flue system to

the top starting collars.

Insert screwdriver

or similar object

here to remove cap.

CUT HERE

Venting

Out Rear

Venting

Out Top

HEAT

SHIELD

DISCARD

INSULATION

SEAL

CAP

SEAL

CAP

HEAT

SHIELD

INSULATION,

DISCARD

BOTH

PIECES