Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13

28

See Notes 3 & 4

Figure 25 vent Termination Minimum Clearances

cauTiON: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT

BE INSTALLED.

* only permitted if veranda, porch, deck or balcony is fully open on a

minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 2.1 M above

a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap

shield is suggested. (See vents components page)

NOTE 2: Termination in an alcove space (spaces open only on one side

and with an overhang) are permitted with the dimensions specified for

vinyl or non-vinyl siding and soffits.

1. There must be 91.4 cm minimum

between termination caps.

2. All mechanical air intakes within 3.0 M of

a termination cap must be a minimum of 91.4 cm below the termination

cap.

3. All gravity air intakes within 91.4 cm of a termination cap must be

a minimum of 30.5 cm below the termination cap.

NOTE 3: Local codes or regulations may require different

clearances.

NOTE 4: Termination caps may be hot. Consider their proximity to

doors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere with

access to the electrical service.

NOTE: Vent system termination is permitted in porch areas with

two or more sides open. You must follow all side walls, overhang

and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper performance

of the appliance when the venting system does not meet these

requirements.

Electrical

Service

v

S

v

S

v

T

D*

v

M

N

P

R

Q

v

= vENT TERMINAL

X

= AIR SUPPLY INLET

= AREA wHERE TERMINAL IS NOT PERMITTED

A

= 30.5 cm .................clearances above grade, veranda,

porch, deck or balcony

B

= 30.5 cm .................clearances to window or door

that may be opened, or to perma-

nently closed window. (Glass)

D*

= 50.8 cm .................vertical clearance to unventilated

soffit or to ventilated soffit located

above the terminal

84.8 cm ..................for vinyl clad soffits and below

electrical service

F

= 22.9 cm ................clearance to outside corner

G

= 15.3 cm .................clearance to inside corner

H

= 91.4 cm .................not to be installed above a gas

meter/regulator assembly within

91.4 cm horizontally from the

center-line of the regulator

I

= 91.4 m ...................clearance to gas service regulator

flue outlet

J

= 22.9 cm ...................clearance to non-mechanical

air supply inlet to building or the

combustion air inlet to any other

appliance

K = 91.4 m .....................clearance to a mechanical

(powered) air supply inlet

L

= 2.1 m .......................clearance above paved

sidewalk or a paved driveway

located on

public property

M* = 50.8 cm ...................clearance under veranda, porch,

deck, balcony or overhang

118.9 m ..................vinyl

(See Note 1)

(See Note 1)

(See Note 2)

Q

MIN

= # termination caps x 3 R

MAX

= (2 / # termination caps) x Q

ACTUAL

Alcove Applications

S = 15.3 cm ....................clearance from sides of elec-

trical service

T = 30.5 cm .....................clearance above electrical

service

(See Note 5)

(See Note 5)

Q

MIN

R

MAX

1 cap

.91 m

2 x Q

ACTUAL

2 caps

1.8 m

1 x Q

ACTUAL

3 caps

2.7 m

2/3 x Q

ACTUAL

4 caps

3.7 m

1/2 x Q

ACTUAL

N = 15.3 cm ..................non-vinyl sidewalls

30.5 cm ..................vinyl sidewalls

P = 2.4 m