OSD Menu

Item

Setting Options (underline indicates factory default)

Select Signal

Sets the waveform to be displayed.

Y, Cb, Cr, R, G, B

Display Type

Sets the display type. When "Line" is selected, data for one line is displayed.

All, Line

Selects the line to be displayed when "Line" is selected.

Select Line: 1

to

2160

Scale

Sets the scale of the wave form monitor.

Automatic

: Sets in accordance with the "Gamma/EOTF" and "Color Range" settings.

IRE, ST 2084 (PQ) Full, ST 2084 (PQ) Limited, Hybrid Log-Gamma, Canon Log, Canon Log
2, Canon Log 3, S-Log2, S-Log3, ARRI (Rec2100-PQ-1K-100), ARRI (Rec2100-HLG-1K-200)

:

Select the scale.

Reference Line

A guide is displayed at the specified position. "Reference Line" is not displayed when "1023" is
selected.

4

to

1023

Reference Level

Sets the range of the reference level. Tints the outside of the range of the reference level.
• In the case of "Gamma/EOTF" corresponding to the HDR range, parts that exceed the HDR range

are tinted.

• When "Color Range"

"Limited", outside the limited range is tinted.

Automatic

: Sets in accordance with the "Gamma/EOTF" and "Color Range" settings.

Manual

: When you select "Manual", sets the reference level.

Reference Level High

: Sets the reference display level (high). "Reference Level High" is not

displayed when "1023" is selected.

468

to

1023

Reference Level Low

: Sets the reference display level (low). "Reference Level Low" is not

displayed when "0" is selected.

0

to

468

Color

Sets the signals to be displayed and the color of signals exceeding the reference level.

Y, Cb, Cr, R, G, B

: Selects the signal.

Selects the color of the selected signal.

White, Red, Green, Blue, Yellow, Cyan, Magenta

Default value of each signal is shown below.
Y (White), Cb (White), Cr (White), R (Red), G (Green), B (Blue)

Reference Level High, Reference Level Low

: Selects the reference level.

White, Red, Green, Blue, Yellow, Cyan, Magenta

Default value of each reference level is shown below.
Reference Level High (Magenta), Reference Level Low (Cyan)

Brightness

Sets the Brightness of the wave form monitor.

Automatic

: Brightness is automatically adjusted according to the contrast value and average

brightness value of the input signal.

Normal, Low

Position

Selects the display position.

Bottom Left, Bottom Right

Note

• This setting becomes invalid in the "Multi View (Dual)" display.

Size

Sets the size of the display.

Large, Middle, Small