Error history log – Eiki LC-X71 LC-X71L User Manual
Page 51
- 51 -
Chassis Description
Error history log
Group No.
Item No.
Data (Error Code)
<-- See table below
91
0
❋
<-- The Latest Error
1
❋
2
❋
3
❋
:
:
:
:
:
:
48
❋
49
❋
Normal
0
-
1000
PJNET,
S5V
1001
AV,
-5V
1002
AV,
S5V
1003
MAIN,
S-5V
1004
M/A,
12V
1005
FAN,
16V
1006
SWFPGA, 1.2V
1007
SWFPGA, 2.5V
1008
ANALOG, 1.8V
Power Failure
1009
FPGA,
1.5V
1010
GAMMA, 15.5V
1011
MAIN,
6V
1012
MAIN,
3.3V
1013
ANALOG, 3.3V
1014
ANALOG,
5V
1015
GAMMA, 1.8V
1016
LAMP FAN, 16V
1017
Factory use
1018
Factory use
1019
Factory use
2000
Sensor A detects abnormal temperature.
2001
Sensor A fails measurement.
2100
Sensor B detects abnormal temperature.
2101
Sensor B fails measurement.
Temperature Error
2102
Sensor B-A temperature error
2200
Sensor C detects abnormal temperature.
2201
Sensor C fails measurement.
2202
Sensor C-A temperature error
3000
Lamp fails on.
Lamp Error
3001
lamp goes out.
3002
Communication error on lamp
Error
Error Code
Error Information
The projector provides the error history log function. To check the logs, you need to enter the service mode and select
Group No. "91" and Item No. "0" to "49". The error code is displayed on the Data column. The description of the error
code is listed on the table below.
How to enter the service mode and selection of the group and item, see "Service Adjustment Menu Operation" on
page 24.