Eiki LC-X71 LC-X71L User Manual
Page 26
- 26 -
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)] mode.
2. Enter the service mode.
3. Connect a digital voltmeter to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
200
”, item no. “
0
” and change data
value to adjust the voltage to be
7.5
±0.05Vdc.
5. Connect a digital voltmeter to test point “
TP561
” (+)
and chassis ground (-).
6. Select item no. “
1
” and change data value to adjust
the voltage to be
7.5
±0.05Vdc.
7. Connect a digital voltmeter to test point “
TP501
” (+)
and chassis ground (-).
8. Select item no. “
2
” and change data value to adjust
the voltage to be
7.5
±0.05Vdc.
v
Video Center adjustment
Electrical Adjustments
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)] mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP533
” (+) and
chassis ground (-).
4. Select group no. “
200
”, item no. “
3
” and change data
value to adjust amplitude “a” to be
10.8
±0.1V.
5. Select item no. “
6
” and change data value to adjust
amplitude “b” to be
3.8
±0.1V.
6. Connect an oscilloscope to test point “
TP563
” (+).
7. Select group no. “
200
”, item no. “
4
” and change data
value to adjust amplitude “a” to be
10.8
±0.1V.
8. Select item no. “
7
” and change data value to adjust
amplitude “b” to be
3.8
±0.1V.
9. Connect an oscilloscope to test point “
TP503
” (+) .
10. Select group no. “
200
”, item no. “
5
” and change data
value to adjust amplitude “a” to be
10.8
±0.1V.
11. Select item no. “
8
” and change data value to adjust
amplitude “b” to be
3.8
±0.1V.
(a)
(b)
b
PSIG adjustment
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)] mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
200
”, item no. “
9
” and change data
value to adjust amplitude “a” to be
10.6
±0.1V.
5. Connect an oscilloscope to test point “
TP561
” (+)
and chassis ground (-).
4. Select group no. “
200
”, item no. “
10
” and change
data value to adjust amplitude “a” to be
10.6
±0.1V.
3. Connect an oscilloscope to test point “
TP501
” (+)
and chassis ground (-).
4. Select group no. “
200
”, item no. “
11
” and change
data value to adjust amplitude “a” to be
10.6
±0.1V.
(a)
black level
black level
n
PC Black Level adjustment
1. Enter the service mode.
2. Connect a digital multimeter to test point “
A
” (+) and
chassis ground (-). (as shown below)
3. Select group no. “
140
”, item no. “
B
” and change data
value to adjust the fan max. output voltage to be
13.5
±0.05V.
4. Select group no. “
140
”, item no. “
C
” and change data
value to adjust the fan min. output voltage to be
5.0
±0.05V.
5. Each fan should be adjusted refer to item 2 - 4.
Note:
The location of each fan is refer to "FAN control stage" of
Chassis Description.
c
Fan Voltage adjustment
Test point "A" Item No."B"
TPFN3
0
TPFN7
2
TPFN6
4
TPFN4
6
FAN1
8
FAN2
10
Item No."C"
Fan No.
1
FN903
3
FN907
5
FN906
7
FN904
9
FN901
FN902
11
FN905