Eiki LC-X71 LC-X71L User Manual

Page 26

background image

- 26 -

1. Receive the 16-step gray scale computer signal with

Input 1 [RGB(Analog)] mode.

2. Enter the service mode.
3. Connect a digital voltmeter to test point “

TP531

” (+)

and chassis ground (-).

4. Select group no. “

200

”, item no. “

0

” and change data

value to adjust the voltage to be

7.5

±0.05Vdc.

5. Connect a digital voltmeter to test point “

TP561

” (+)

and chassis ground (-).

6. Select item no. “

1

” and change data value to adjust

the voltage to be

7.5

±0.05Vdc.

7. Connect a digital voltmeter to test point “

TP501

” (+)

and chassis ground (-).

8. Select item no. “

2

” and change data value to adjust

the voltage to be

7.5

±0.05Vdc.

v

Video Center adjustment

Electrical Adjustments

1. Receive the 16-step gray scale computer signal with

Input 1 [RGB(Analog)] mode.

2. Enter the service mode.
3. Connect an oscilloscope to test point “

TP533

” (+) and

chassis ground (-).

4. Select group no. “

200

”, item no. “

3

” and change data

value to adjust amplitude “a” to be

10.8

±0.1V.

5. Select item no. “

6

” and change data value to adjust

amplitude “b” to be

3.8

±0.1V.

6. Connect an oscilloscope to test point “

TP563

” (+).

7. Select group no. “

200

”, item no. “

4

” and change data

value to adjust amplitude “a” to be

10.8

±0.1V.

8. Select item no. “

7

” and change data value to adjust

amplitude “b” to be

3.8

±0.1V.

9. Connect an oscilloscope to test point “

TP503

” (+) .

10. Select group no. “

200

”, item no. “

5

” and change data

value to adjust amplitude “a” to be

10.8

±0.1V.

11. Select item no. “

8

” and change data value to adjust

amplitude “b” to be

3.8

±0.1V.

(a)

(b)

b

PSIG adjustment

1. Receive the 16-step gray scale computer signal with

Input 1 [RGB(Analog)] mode.

2. Enter the service mode.
3. Connect an oscilloscope to test point “

TP531

” (+)

and chassis ground (-).

4. Select group no. “

200

”, item no. “

9

” and change data

value to adjust amplitude “a” to be

10.6

±0.1V.

5. Connect an oscilloscope to test point “

TP561

” (+)

and chassis ground (-).

4. Select group no. “

200

”, item no. “

10

” and change

data value to adjust amplitude “a” to be

10.6

±0.1V.

3. Connect an oscilloscope to test point “

TP501

” (+)

and chassis ground (-).

4. Select group no. “

200

”, item no. “

11

” and change

data value to adjust amplitude “a” to be

10.6

±0.1V.

(a)

black level

black level

n

PC Black Level adjustment

1. Enter the service mode.
2. Connect a digital multimeter to test point “

A

” (+) and

chassis ground (-). (as shown below)

3. Select group no. “

140

”, item no. “

B

” and change data

value to adjust the fan max. output voltage to be

13.5

±0.05V.

4. Select group no. “

140

”, item no. “

C

” and change data

value to adjust the fan min. output voltage to be

5.0

±0.05V.

5. Each fan should be adjusted refer to item 2 - 4.

Note:
The location of each fan is refer to "FAN control stage" of
Chassis Description.

c

Fan Voltage adjustment

Test point "A" Item No."B"

TPFN3

0

TPFN7

2

TPFN6

4

TPFN4

6

FAN1

8

FAN2

10

Item No."C"

Fan No.

1

FN903

3

FN907

5

FN906

7

FN904

9

FN901
FN902

11

FN905