Christie M Series WU14K-M WUXGA 3DLP Projector (No Lens) User Manual
Page 85

Channel
Group
Name
Description
Default
value
Notes
16
Lamp/Power Lamp/Power
functions
Lamp Power
Scaled as % of total
control range,.
Examples are given for
350W:
00 0% 300 Watt
—
10 310 Watt
—
20 320 Watt
—
30 330 Watt
—
40 340 Watt
—
50 350 Watt
—
60 360 Watt
—
70 100% 370 Watt
86 LOAD
171 EXECUTE
Lamp Mode
90 Auto select Single Lamp
95 Dual Lamp Mode
Power Mode
100 Power Off (Switch
lamps off, cool lamps down
and go to Standby mode)
105 Power On (Switch
lamps on, warm up mode)
255
18
Colormetry
Contrast
0 to 255 Scaled as % of
total range, which is 0 to
100
128
19
Colormetry
Gamma
0 to 255 Scaled as % of
total range, which is -100
to 100
128
17
Colormetry
Brightness
0 to 255 Scaled as % of
total range, which is 0 to
100
128
DMX/ArtNET
M Series User Guide
85
020-101948-02 Rev. 1 (08-2018)
Copyright
©