beautypg.com

Installing the lamps, Disposing of the lamp – Christie M Series WU14K-M WUXGA 3DLP Projector (No Lens) User Manual

Page 64

background image

200W and 350W

450W

3. Slowly slide the lamp out of the compartment.
4. For the second lamp, repeat steps 1 to 3.
5. Check the aluminum tape on the lamp door. If there are any signs of adherence degradation,

replace the tape.

Installing the lamps

If replacing lamps due to a lamp explosion; both lamps should be removed from the lamp housing

area, including fan #4 and exhaust ducts. Ensure they are carefully vacuumed before lamp

replacement.

Warning! If not avoided, the following could result in death or serious injury.

UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective
safety clothing must be worn when performing optical adjustments or servicing the product.

1. Carefully insert the lamp into the lamp housing with the connector oriented to the top.
2. Seat the lamp onto the mating connector in the projector and push the lamp forward until fully

seated.

3. Secure the lamp with the three captive screws.
4. Close and secure the lamp door.

Disposing of the lamp

The lamp is extremely hazardous. Do not dispose of in regular trash.
For warranty claims:

1. Carefully repack the lamp with the original shipping material and carton.
2. Enclose the completed RMA claim form that came with the lamp.
3. Ship the lamp to the nearest Christie service depot for evaluation.

For safe disposal:

1. Pack the lamp into its original carton (without the packaging material).
2. Tape the box up securely along its seams.
3. Discard as industrial waste, in accordance with your local regulations.

Monitoring and maintaining the projector

M Series User Guide

64

020-101948-02 Rev. 1 (08-2018)

Copyright

©

2018 Christie Digital Systems USA, Inc. All rights reserved.