Christie M Series WU14K-M WUXGA 3DLP Projector (No Lens) User Manual
Page 78

Channel Group
Name
Description
Default
Value
Notes
120 to 129 Slot 3, Input 1
—
170 to 179 Slot 3, Input 6
180 to 189 Slot 4, Input 1
—
230 to 239 Slot 4, Input 6
15
Image
Image
Freeze
0-85 Unfreeze image
172-255 Freeze Image
0
16
Lamps/
Power
Power
0-85 Power Off (Switch lamps
off, cool lamps down and go to
Standby mode)
172-255 Power On (Switch
lamps on, warm up mode)
128
A five second timer is used
before executing a power
state change. If the slider
moves out of the On/Off
range within the five
seconds, the timer is
cancelled.
Does not change power stat
on default.
17
Image
Size
0 to 255 Scaled as % of total
control range, which is 200 to
4000
67
18
Image
Vertical
Stretch
0 to255 Scaled as % of total
control range, which is 200 to
3000
91
19
Setup
Functions
Projector
Orientation
0-49 Front Projection
50-99 Rear Projection
100-149 Front Projection
Inverted
150-199 Rear Projection
Inverted
255
Does not change projector
orientation on default.
20
Setup
Functions
On Screen
Display
0-85 OSD Off
172-255 OSD On
128
Does not change OSD on
default.
21
Setup
Functions
Lens
Calibrate
172-255 Run calibration
0
Locked by channel
“Lens shift enable”
22
Setup
Functions
Lamp Power
Scaled as % of total control
range.
Examples are given for 350W
lamps:
0 0% 300 Watt
—
127 50% 335 Watt
—
255 100% 370 Watt
255
Depends on what lamps are
used, power rating may be
different scale.
DMX/ArtNET
M Series User Guide
78
020-101948-02 Rev. 1 (08-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.