FieldServer Configuration Manual

Page 67 of 90

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com

Tel: (408) 262-2299 Fax: (408) 262-2269 Toll Free: (888) 509-1970 email: [email protected]

10.3.6 Server Name

NOTE: The Client Node Descriptors used to have to have CONFIG.CSV file entries that describe the adapter and IP
address
of the AC2PA connection and backup connection – this is no longer required, the Client Node Descriptor
now only needs to be given the Server_Name of the source of the data. The Server names are configured in the
HSB_P.INI and HSB_S.INI files for each physical FieldServer.

10.3.7 Application example using Hot Standby Mode 2

Consider the application in Figure XV where the highest redundancy level possible is required. The application has
a mixture of Single and Dual port Servers, and Dual Redundant Clients.

Figure XV – Hot Standby Mode 2 Application.

Primary and auxillary FS-X40 FieldServers are used to allows RS-232 connection to more than 8 PLC’s.

The dark blue boxes represent the physical FieldServers.

The light gray boxes represent the information Servers

The thin lines represent the RS-232/RS-485 serial connections.

The physical Ethernet connections are NOT represented.

The thick solid and dotted lines represent the logical Ethernet connections possible from FieldServer 1 to
all possible sources of data. Connections from FieldServer 2 are not shown, but do exist.

Redundancy is Achieved as Follows:

When FieldServer 1 fails, FieldServer 2 takes over and remains Active until FieldServer 2 fails at which
point FieldServer 1 takes over.

If the PEX tier of FieldServer1 fails, the SCADA Tier of FieldServer 1 will get the data from the PEX Tier of
FieldServer 2.

PLC5

PLC6

PLC7

PLC8

PLC1

PLC2

PLC3

PLC4

UPS

EPLCG1

Information

Client

Virtual Bridge on Tier 2

(PEX Tier)

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

Virtual Bridge on Tier 1

(scada Tier)

Virtual Bridge on Tier 2

(PEX Tier)

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

Virtual Bridge on Tier 1

(scada Tier)

Information Server

FieldServer 3

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

Information Server

FieldServer 4

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

P

1

N

2

N

1

V

N

R

2

R

1

P

8

P

7

P

6

P

5

P

4

P

3

P

2

PLC10

PLC9

Physical

FieldServer 2

(primary)

Physical

FieldServer 1

(primary)

Physical

FieldServer 3

(auxiliary)

Physical

FieldServer 4

(auxiliary)