Set Processor Time Block (9970)
This block is constructed by the processor to request the module’s time. The
following table describes the format of this block.
Word Offset in Block Data Field(s)
Description
0
Block ID
This field contains the value of 9970 identifying
the block type to the module.
1 to 6
Not Used
Not Used
When the module receives this block, it immediately constructs a response block
containing the modules current time. The following table describes the format of
this block.
Word Offset in Block Data Field(s)
Description
0
Block Read ID
This field contains the block identification code of
9970 for the block.
1
Block Write ID
This is the next block requested by the module.
2
Year
This field contains the four-digit year for the new
time value.
3
Month
This field contains the month value for the new
time. Valid entry for this field is in the range of 1
to 12.
4
Day
This field contains the day value for the new time.
Valid entry for this field is in the range of 1 to 31.
5
Hour
This field contains the hour value for the new
time. Valid entry for this field is in the range of 0
to 23.
6
Minute
This field contains the minute value for the new
time. Valid entry for this field is in the range of 0
to 59.
7
Seconds
This field contains the second value for the new
time. Valid entry for this field is in the range of 0
to 59.