Diagnostics and Troubleshooting

ILX56-MM ♦ ControlLogix Platform

User Manual

InRAx Message Manager for Industrial Communication

Page 72 of 112

ProSoft Technology, Inc.

February 6, 2012

Runtime Triggers Status
To open the Runtime Interface Status

page, click the S

TATUS

tab, then click the

R

UNTIME

tab, then click the I

NTERFACE

tab.

The Runtime Interfaces Status page contains a table that shows all of the

Interfaces that are defined in the scanner along with information about each

Interface. The information about each Interface includes the following.

Parameter

Description

Count

Indicates the number of times the Interface has fired.

Packet Retry Count

Indicates the number of times a packet send was re-sent to the

controller.

Packet Error Count

Indicates the number of times an error occurred sending a packet to the

controller.

Tag Access Count

the total number of times that the tags in the controller have been

accessed ( read or write).

Tag Access Error Count

The total number of errors that have occurred in while reading or writing

tags in the controller.

Error State Flag

the current error number occurring in the driver or device. This gets

cleared when their is no error.

Details

A string that describes the last error that occurred in the driver or

device. This does NOT get cleared when the error goes away.


To update the status while viewing the Runtime Interface Status page, click the
R

EFRESH

button.

To reset all of the runtime statistics while viewing the Runtime Interface Status

page, click the R

ESET

S

TATISTICS

button.