Administration

ILX56-MM ♦ ControlLogix Platform

User Manual

InRAx Message Manager for Industrial Communication

Page 26 of 112

ProSoft Technology, Inc.

February 6, 2012

System functions you can execute on the module include

Function

Description

Backup

Choose which settings from the module you would like to backup by

checking C

ONFIGURATION

and/or A

DMINISTRATIVE

S

ETTINGS

. Then click the

B

ACKUP

button to backup the current module configuration(s) to a file on

your computer.
A

DMINISTRATIVE

S

ETTINGS

backs up all module configuration settings,

including network settings, device name, and so on.
C

ONFIGURATION

backs up the only the information that pertains to the

transfer of data. You can then use this backup file to configure another

module with the same settings.

Restore

Click the B

ROWSE

button to select a previously saved configuration file

from your computer.
Click the R

ESTORE

button to restore the module to the state saved in the

configuration file.
The module is rebooted after the configuration is restored. You will be

prompted to confirm the configuration restore and reboot.

Set Log Level

Set the log level at which the scanner module will record events.

Level 1 logs errors only. This is the recommended setting for most
applications.

Levels 2

through 4

log informational events in increasing detail. Use

these levels for troubleshooting and support.

Level 0 logs only internal system errors.

The scanner must be restarted before the new log level will take effect.

Click the R

EINITIALIZE

button to restart the scanner. You will be prompted

to confirm the reinitialize.

Clear Event Logs

Clears the entire Event Log from the module. This cannot be undone.

Update

You can update the module's firmware from this page. You should only
update the firmware if you have been directed to do so by ProSoft
Technical Support.

Click the B

ROWSE

button to select the firmware file on your computer.

Firmware files have the file extension "fwa".
Click the U

PDATE

button to perform the update on the module. You will be

prompted to confirm the update.

IMPORTANT: Do not cycle power or disconnect the

Ethernet cable until the update is complete.

Important: You must clear your browser's cache (Tools/Delete Browsing
History/Temporary Internet Files) after rebooting the module to ensure

the old pages have been cleared from your browser's memory.

Reboot

Click the R

EBOOT

button to reboot the module. You will be prompted to

confirm the reboot.

Note: You must be logged on as a user with Administrator privilege to modify the settings on this
page.