beautypg.com

ProSoft Technology ILX56-MM User Manual

Page 101

background image

ILX56-MM ♦ ControlLogix Platform

Reference

InRAx Message Manager for Industrial Communication

User Manual

ProSoft Technology, Inc.

Page 101 of 112

February 6, 2012

Error Code

Description

228h

S7L duplicate address

229h

S7L no device

22Ah

S7L general

240h

Dev IpAddr required

241h

Tag Address required

242h

Tag Address format

243h

Tag S7Type required

244h

Tag S7Type format

245h

Too many configured PLCs

Scanner Errors

Error Code

Description

801h

General (internal) error

802h

Unsupported functionality

803h

Out of memory

804h

Timeout error

805h

Bad parameter

806h

Access denied (probably instance not opened)

807h

Aborted by user

808h

Tag not readable

809h

Tag not writable

850h

Comparison failure

851h

Comparison overflow

852h

Tag data conversion error

853h

Tag data conversion overflow

As you can see, the actual transfer mechanism in the ILX56-MM is far removed

from the messaging layer. Therefore, many of the errors pertain to the scanner,

driver, and Application Programming Interface (API).
If the error count value is not cleared, then the count will rollover to zero when it

reaches the decimal value of 65535 and must be incremented again.
The "Transfer Error Count" will NOT necessarily correlate with the error counts

shown on the "Status-Runtime-Transfer Lists" page.
If status data transfer fails, it will be logged into the event log.