PLANET ICS-2100 User Manual
Page 50

User’s Manual of ICS-210x
-46-
Example: Two ICS-210x with Pair Connection mode
One be configured as
Pair Connection – Local
(Master)
The other one be configured as
Pair Connection – Remote
(Slave)
Via the RS-485 interface, the external scanners, speed dome cameras and PTZ receivers can be controlled by the keyboard
which provides upward, downward, leftward, rightward, clockwise and counterclockwise with the joystick. In this case, we use
two ICS-210x to extend the distance between an IP surveillance PT Camera and a Control keyboard. Both of the two
equipments are implemented with RS-485 interface.
The two of the ICS-210x master and slave with below settings:
ICS-210x Master
Connect to
Control Keyboard
IP Address / Subnet Mask
192.168.0.100 / 255.255.255.0
Operation Mode
Mode: Pair Connection – Local
TCP Port Number : 1024
Serial Mode:
RS-485
Baudrare:
9600
Character Bits:
8
Parity Type :
none
Stop Bit :
1
Serial Port Configuration
Hardware Flow Control:
none
ICS-210x Slave
Connect to
Speed Dome Camera, PTZ or Scanner
IP Address / Subnet Mask
192.168.0.101 / 255.255.255.0
Mode:
Pair Connection – Remote
Remote Host IP Address :
192.168.0.100
Operation Mode
Remote Host Port Number :
1024
Serial Mode:
RS-485
Baudrare:
9600
Character Bits:
8
Parity Type :
none
Stop Bit :
1
Serial Port Configuration
Hardware Flow Control:
none
Topology:
Figure 4-50 Two ICS-210x configured with Pair-Connection