PLANET LRP-822CS User Manual
Page 324
User’s Manual of LRP-822CS
324
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly (default).
Delta: Calculate the difference between samples.
Rising Threshold
Rising threshold value (0–2147483647)
Falling Threshold
Falling threshold value (0–2147483647)
Rising Event
Event to fire when the rising threshold is crossed
Falling Event
Event to fire when the falling threshold is crossed
Owner
Specify an owner for the alarm
Buttons
: Click to apply changes.
Figure 4-14-6: RMON Alarm Status Page Screenshot
The page includes the following fields:
Object
Description
Index
Indicates the index of Alarm control entry
Sample Port
Display the current sample port
Sample Variable
Display the current sample variable
Sample Interval
Display the current interval
Sample Type
Display the current sample type
Rising Threshold
Display the current rising threshold
Falling Threshold
Display the current falling threshold
Rising Event
Display the current rising event
Falling Event
Display the current falling event
Owner
Display the current owner
Action
Click
to delete RMON alarm entry