6 multicast throttling setting – PLANET LRP-822CS User Manual
Page 183
User’s Manual of LRP-822CS
183
4.7.6 Multicast Throttling Setting
Multicast throttling sets a maximum number of multicast groups that a port can join at the same time. When the maximum
number of groups is reached on a port, the switch can take one of two actions; either “deny” or “replace”. If the action is set to
deny, any new multicast join reports will be dropped. If the action is set to replace, the switch randomly removes an existing
group and replaces it with the new multicast group.
Once you have configured multicast profiles, you can assign them to interfaces on the LRP Managed Switch. Also you can set
the multicast throttling number to limit the number of multicast groups an interface can join at the same time. The MAX Group
and Information screens in
Figure 4-7-34
&
Figure 4-7-35
appear.
Figure 4-7-34 Max Groups and Action Setting Page Screenshot
The page includes the following fields:
Object
Description
IP Type
Select IPv4 or IPv6 from this drop-down list
Port Select
Select port number from this drop-down list
Max Groups
Sets the maximum number of multicast groups an interface can join at the same
time.
Range: 0-256;
Default:
256
Action
Sets the action to take when the maximum number of multicast groups for the
interface has been exceeded.
(Default: Deny)
-
Deny - The new multicast group join report is dropped
-
Replace - The new multicast group replaces an existing group