User’s Manual of LRP-822CS
31
1.
Before we connect LRP Managed Switch to the other network device, we have to make sure both sides of the Long
Reach Ethernet coaxial extender / transceiver are with the same media type.
2.
Check whether the coaxial cable type matches with the Long Reach Ethernet coaxial extender / transceiver requirement.
To connect to LRP Managed Switch, please use the coaxial cable with 75Ω BNC plug with one side being the BNC
plug connector type.
To connect to Long Reach Ethernet coaxial extenders, please use the coaxial cable with one side being the 75Ω
BNC plug connector type.
Because there are various resistance values in the category of RG-59/U or RG-6/U cables, please
take care of the conditions of the resistance value of cables as follows:
Coaxial Cable Type
RG-59/U Less
than
30Ω/1000 ft.
RG-6/U Less
than
12Ω/1000 ft
In the installation steps below, this Manual uses Long Reach Ethernet coaxial extender as an
example.
Connect the Coaxial Cable
1.
Insert the coaxial cable with one side being the 75Ω BNC plug connector into the Long Reach Ethernet coaxial interface.
2.
Connect the other end of the cable to a device with Long Reach Ethernet coaxial extender installed.
3.
Tighten the BNC male connector gently.
Figure 2-1-8 How to insert the coaxial cable from LRP Managed Switch
4.
Enable Long Reach Power over Ethernet function for the all LRP ports from WebUI