beautypg.com

PLANET FGSW-2620VM User Manual

Page 69

background image

User’s Manual of FGSW-Series

Figure 4-3-6:

Port Sniffer interface

The page includes the following fields:

Object

Description

Sniffer Type:

Select a sniffer mode:

Disable
Rx
Tx
Both

Analysis (Monitoring) Port:

It’ means Analysis port can be used to see the traffic on another port you want to

monitor. You can connect Analysis port to LAN analyzer or netxray.

Monitored Port:

The port you want to monitor. The monitor port traffic will be copied to Analysis

port. You can select one monitor ports in the switch. User can choose which port

that they want to monitor in only one sniffer type.

1

When the Mirror Mode set to RX or TX and the Analysis Port be selected, the packets
to and from the Analysis Port will not be transmitted. The Analysis Port will accept only
COPPIED packets from the Monitored Port.

2

If you want to disable the function, you must select monitor port to none.

69

This manual is related to the following products: