2 electrical characteristics, 1 dc characteristics, Electrical characteristics – Avago Technologies LSI53C120 User Manual
Page 38: Dc characteristics, No connect pins, Absolute maximum stress ratings
3-8
Specifications
3.2 Electrical Characteristics
This section provides information about the DC and AC characteristics
for the LSI53C120 Ultra SCSI Bus Expander.
3.2.1 DC Characteristics
lists the maximum stress ratings for the LSI53C120 device.
Table 3.7
No Connect Pins
No Connects
Pin
Type
Description
NC
39, 40, 42, 43, 120,
123, 124
No external connection required.
Require pullups
1, 2, 128
Requires a pullup.
Require pulldown
125
Requires a pulldown with a 1K ohm resistor.
Table 3.8
Absolute Maximum Stress
1
Ratings
Symbol
Parameter
Min
Max
Unit
Test Conditions
T
STG
Storage temperature
-55
150
°
C
–
V
DD
Supply voltage
-0.5
7.0
V
–
V
IN
Input Voltage
V
SS
- 0.5
V
DD
+ 0.5
V
–
I
LP
2
Latch-up current
±
150
–
mA
–
ESD
3
Electrostatic discharge
–
2K
V
MIL-STD 883C, Method 3015.7
1. Stresses beyond those listed above may cause permanent damage to the device. These are stress
ratings only; functional operation of the device at these or any other conditions beyond those indi-
cated in the Operating Conditions section of the manual is not implied.
2.
-2V < VPIN < 8V
3.
SCSI pins only