KEPCO MST Series User Manual
Page 24

2-6
MST SERIES 061813
8. Verify that DVM connected across pins 5 and 2 of DC Output connector reads 0V.
9. Set switch S1 to CLOSE SENSE position and issue commands from the host computer to
set the MST Power Module to Voltage Mode, program output voltage to –E
MAX
, current limit
to I
MAX
and enable the output.
10.Verify that VOLTAGE MODE, POLARITY REVERSED and OUTPUT ENABLED indicators
on front panel are on and VOLTS meter on front panel indicates E
MAX
.
11. Connect DVM across pins 5 (+) and 2 (–) of the DC Output connector (Figure 2-3) and verify
that DVM reads –E
MAX
.
12.Issue commands from the host computer to read back voltage; verify that readback voltage
is –E
MAX
.
13.Set switch S1 (Figure 2-3) to OPEN SENSE position. Verify that front panel OUTPUT
ENABLED indicator is off, and VOLTS meter reads 0V.
14.Verify that DVM connected across pins 5 and 2 of DC Output connector reads 0V.
15.Set switch S1 to CLOSE SENSE position and issue commands from the host computer to
set the MST Power Module to Current Mode, program output current to I
MAX
and voltage
limit to +E
MAX
.
16.Verify that CURRENT MODE indicator on front panel is on and AMPS meter on front panel
indicates I
MAX
.
17.Issue commands from the host computer to read back current; verify that read back current
is I
MAX
.
SCPI COMMANDS
CIIL COMMANDS
FUNC1:MODE VOLT
VOLT1 –36; CURR1 5; OUTP ON
FNC DCS :CH1 SET VOLT –36 SET CURL 5
CLS :CH1
SCPI COMMANDS
CIIL COMMANDS
MEAS1:VOLT?
FNC DCS VOLT :CH1
INX VOLT
FTH VOLT
SCPI COMMANDS
CIIL COMMANDS
FUNC1:MODE CURR
CURR1 5; VOLT1 36
FNC DCS :CH1 SET CURR 5 SET VLTL 36
SCPI COMMANDS
CIIL COMMANDS
MEAS1:CURR?
FNC DCS CURR :CH1
INX CURR
FTH CURR