SECTION 2 - INSTALLATION

2.1

UNPACKING AND INSPECTION

This instrument has been thoroughly inspected and tested prior to packing and is ready for
operation. After careful unpacking, inspect for shipping damage before attempting to operate.
Perform the preliminary operational check as outlined in PAR. 2.5. If any indication of damage is
found, file an immediate claim with the responsible transport service.

NOTE

If the Power Modules are shipped pre-installed in the RA 55 Rack Adapter, each
module is secured to the RA 55 Rack Adapter by two shipping screws. These
screws must be removed from the bottom of the rack adapter, otherwise the mod-
ules cannot be removed from the rack adapter.

2.2

TERMINATIONS AND CONTROLS

a. Internal Calibration Controls: Refer to Figure 2-4 and Table 2-1.

b. Front Panel: Refer to Figure 2-1 and Table 2-2.

c. Rear Panel: Refer to Figure 2-1 and Table 2-3.

2.3

A-C INPUT REQUIREMENT

MST Power Modules operate from single-phase a-c mains power over the specified voltage and
frequency ranges without adjustment or modification.

2.4

COOLING

The power transistors and rectifiers in the MST Power Module are maintained within their oper-
ating temperature range by means of internal heat sink assemblies cooled by internal fans.
PANEL OPENINGS AND THE TOP OF THE CASE MUST BE KEPT CLEAR FROM
OBSTRUCTIONS TO INSURE PROPER AIR CIRCULATION. Maximum ambient temperature
for installed MST modules is 45°C. See technical manuals for RA 55 or CA 400 rack adapters

TABLE 2-1. FUNCTIONS OF INTERNAL CONTROLS

REFERENCE

DESIGNATION

CONTROL

PURPOSE

R49

+5 V REF

This is a primary adjustment for the analog circuits.

R11

EO Zero

This control is used to adjust the output voltage of the Power Module to
zero. EO Zero calibrates the Power Module in the Voltage mode.

R51

IO Zero

This control is used to adjust the output current of the Power Module to
zero. IO Zero calibrates the Power Module in the Current mode.

R50

Current Sensing Zero

This adjustment calibrates the current monitor amplifier to zero.

R52

Full Scale Current Adjust

This adjustment calibrates the programmed full scale value.

R47

VREF

This is a full scale voltage adjustment.

R48

IREF

This is a current read back accuracy adjustment.