Precision Digital PD6300 User Manual
Page 43
Model PD6300 Pulse Input Rate/Totalizer
Instruction Manual
43
K-Factor Calibration (Factor)
The meter may be calibrated using the K-Factor function. Most flowmeter
manufacturers provide this information with the device. Enter the
K-Factor
(Factor) menu and select the decimal point with highest reso-
lution possible and program the k-factor value (i.e. pulses/gal). The me-
ter will automatically calculate the flow rate using the k-factor and the
time base selected.
ddd.ddd
factor
Factor
prog
d.ddddd
factor
1.8925
6
factor
Multi-Point Calibration & Scaling
The meter is set up at the factory for 2-point linear calibration. The num-
ber of points for multi-point calibration/scaling is set up in the Advanced
Features
menu. Up to 32 linearization points may be selected. See page
76 for details.