Precision Digital PD6300 User Manual
Page 38
Model PD6300 Pulse Input Rate/Totalizer
Instruction Manual
38
Setting the Input Signal (Input)
There are two switches, located to the right of the input connector, which
must be configured according to the input level and type. Jumper J4 lo-
cated inside the meter, behind the input signal connector, is used to se-
lect the excitation voltage (24 V*, 10 V or 5 V) which is supplied to the
P+ and P- wiring terminals.
*Default setting
Enter the Input menu to enable or disable the totalizer features.
Setting the Totalizer Features (total)
Enable or disable the totalizer features by selecting “Yes” or “no” after
the input type has been set up. If the totalizer features are disabled, all
the totalizer features and functions are hidden from the menus.
Note: The totalizer continues working in the background.
Setting the Decimal Point (dEc pt)
The decimal point may be set with up to five decimal places or with no
decimal point at all. The rate, total, and grand total decimal points are
independent.
Pressing the Right arrow moves the decimal point one place to the right
until no decimal point is displayed then it moves to the leftmost position.