PELLET STOVES

Chapter 4

INSTALLATION AND USE MANUAL

page

46

Operation

Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited

Failure when carrying out works of maintenance, cleaning

and repair to adopt all necessary measures and

precautions

Tampering with the safety devices.

Removing the safety devices.

Failure to connect the stove to an efficient system for the

discharge of smoke.

Failure to check in advance that the room where the stove

is to be installed is adequately ventilated.

7.2. ALARM SIGNALLING

If there is an operating anomaly, the stove goes into alarm shutdown
mode and informs the user of the type of problem that has occurred via

a 3-figure code displayed on the rear emergency panel.
The alarm is permanently signalled by the corresponding 3-figure code,

by a flashing red light on the emergency panel, and, for the first ten

minutes of the alarm, by a periodic acoustic signal. To take the stove

out of alarm conditions and restore its normal operation, read the

instructions in the next two paragraphs.
The table below describes the possible alarms signalled by the stove,

associated to the respective code that appears on the emergency panel,

and useful suggestions to solve the problem.

MESSAGE ON

DISPLAY

TYPE OF PROBLEM

SOLUTION

A01

Fire fails to ignite

Check the level of pellets in the hopper.

Check that the grate is properly inserted in its housing

and does not have any obvious unburnt incrustations;

Check whether the ignition plug heats.

A02

Fire extinguishes abnormally

It derives from a shutdown due to lack of fuel (hopper

empty).

A03

Pellet tank temperature exceeds foreseen

safety limit.
Overheating of the stove body

The structure is too hot because the product has been

operating for too long at maximum power, or it is

poorly ventilated, or the air fans are faulty. When the

stove is sufficiently cold, press button B of the control

panel or OFF on the remote control to cancel the alarm

A03. Once the alarm is cancelled it is possible to relight

the stove normally.

A04

The temperature of the smoke discharge has

exceeded pre-set safety limits

The stove will shut off automatically. Let the stove cool

off for a few minutes, then re-light it.
Check smoke release and the type of pellet being used.

A05

Flue pipe obstruction - wind - door open.

Check fume conduit and door closure.

A06

The smoke extractor is not able to provide the

primary air required for combustion.

Draught difficulties or clogging of grate.

Check whether the grate is clogged by incrustation and

clean as required.

Control and if necessary clean the smoke duct and the

air intake.

A08

Flue-gas exhaust fan broken

Check that the smoke fan compartment is clean and if it

is dirt that is blocking it.
If insufficient, the smoke fan is defective. Call an

authorized service centre to make the replacement.

A09

The smoke probe is defective and does not

properly measure the temperature of the

discharge smoke

Contact an authorized service centre to replace the

component.