Theoretical notions for installation

Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited

2.3. OPERATING AREA

For proper functioning and a good temperature distribution, the stove

should be positioned in a location where it is able to take in the air

necessary for combustion of the pellets (about 40 m

3

/h must be

available), as laid down in the standard governing the installation and

in accordance with local national standards.
The volume of the room must not be less than 30 m

3.

The air must come in through permanent openings made in walls (in

proximity to the stove) which give onto the outside, with a minimum

cross-section area of 100 cm

2.

These openings must be made in such a way that it is not possible for

them to be obstructed in any way.
Alternatively, the air can be taken from rooms adjacent to the one
which needs ventilating, as long as they are provided with an air intake

from the outside, and are not used as bedrooms or bathrooms, and

provided there is no fire risk such as there is for example in garages,

woodsheds, and storerooms, with particular reference to what is laid

down in current standards.

It is not permissible to install the stove in bedrooms,

bathrooms or showers, or in a room where another

heating appliance is installed (fireplace, stove etc.)

which does not have its own independent air intake.
Locating the stove in a room with an explosive

atmosphere is prohibited.

The floor of the room where the stove is to be

installed must be strong enough to take its weight.













If the room contains objects which are believed to be particularly

delicate, such as drapes, sofas and other furniture, their distance from

the stove should be considerably increased.

If the floor is wooden, we recommend the use of a

floor guard in compliance with the applicable

standards in force in the country of installation.

Example of pellet stove installation

SUITE/CLUB/MUSA/
NIMA/TOBA

Non-flammable
walls

Flammable walls

Air version

A=5cm
B=5cm

A=5cm
B=10cm

Comfort Air version
with diffuser

A=15cm
B=15cm

A=20cm
B=20cm

Ducted Comfort Air
version

A=5cm
B=15cm

A=5cm
B=20cm