Sealey VS8221 User Manual
Page 16

Page 16
Original Language Version
VS8221 Issue:2(I) - 06/08/13
5.4. Tool and Work Area Set-Up
CAUTION: Set up the borescope and work area according to these
procedures to reduce the risk of injury from electric shock,
entanglement, and other causes and prevent tool damage.
5.4.1. Check work area for:
Sufficient lighting.
DO NOT work in area until flammable sources have been identified and
corrected. The tool is not explosion proof and can cause sparks.
DO NOT use the tool while standing in water.
5.4.2. Check the area and determine if VS8221 borescope is the correct tool for
the job.
5.4.3. Check the access points to the area.
5.4.4. Check if there is any electric power supplied to the area to be inspected.
5.4.5. Check if any liquids will be encountered during the inspection.
5.4.6. The Image head and cable are waterproof to a depth of 3m (10’), Greater
depths may cause leakage into the imager head and cable and cause
electric shock or damage the tool. The display unit is not waterproof and
should not be exposed to wet conditions.
5.4.7. Check if any chemicals are present, especially in the case of drains.
Chemicals may damage the tool.
5.4.8. Check the temperature of the area. The working temperature of the tool is
between 32°F (0°C) and 113°F (45°C).
5.4.9. Check if any moving parts are present in the area.
5.4.10. Make sure that the tool has been properly inspected.
5.4.11. Install the correct accessories for use in the appropriate application.
• CAUTION: Make sure the borescope has been powered off before
performing maintenance.
5.4.12.
Tool maintenance must be performed only by qualified repair personnel.
5.4.13.
Maintenance performed by unqualified personnel could cause injury.
5.4.14.
When maintaining, use only identical replacement parts. Use of unauthorised
parts or failure to follow maintenance instructions will invalidate warranty.
5.4.15.
DO NOT
attempt to take the tool apart.
5.4.16.
Follow instructions to change accessories.
5.4.17.
DO NOT
use acetone to clean the tool. Instead,
use only alcohol to swab the
connections
. Avoid rubbing too hard on the LCD screen. After using, wipe
the display unit clean, gently with a dry cloth.
5.4.18.
Always handle the tool with care. It is not shock-resistant.
5.4.19.
DO NOT disassemble the tool beyond what is shown in the manual.Doing so
will void the warranty.