Cli setup, Proper boot sequence, Common errors – Enterasys Networks 8000/8600 User Manual
Page 88: Helpful cli commands for debugging
Installing the Hardware
76
Enterasys X-Pedition 8000/8600 Getting Started Guide
SSR-SERC-04-AA
E8.3.0.0
CLI Setup
Enter the following command at the CLI before
implementing any configurations.
1.
Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #
2.
You may now begin configuring ports on the
SSR-SERC-04-AA. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual for details.
Proper Boot Sequence
•
Firmware loads.
•
The control module for the chassis should indicate
that the SSR-SERC-04-AA was detected and is
operating correctly.
•
The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).
Common Errors
•
The ER16-SERC-04-AA is not inserted properly or
seated completely in the chassis
•
Connectors for the connected lines are not seated
properly.
Helpful CLI Commands for Debugging
•
System show hardware
•
System show version
•
Port show port status se.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).
•
System show bootlog
SSR-SERCE-04-AA
E8.3.0.0
CLI Setup
Enter the following command at the CLI before
implementing any configurations.
1.
Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #
2.
You may now begin configuring ports on the
SSR-SERCE-04-A. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual for details.
Proper Boot Sequence
•
Firmware loads.
•
The control module for the chassis should indicate
that the SSR-SERCE-04-A was detected and is
operating correctly.
•
The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).
Common Errors
•
The ER16-SERCE-04-A is not inserted properly or
seated completely in the chassis
•
Connectors for the connected lines are not seated
properly.
Helpful CLI Commands for Debugging
•
System show hardware
•
System show version
•
Port show port status se.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).
•
System show bootlog
Table 19. Line card installation notes (Continued)
Minimum
Firmware
Restrictions
Special Instructions