Installing the control module – Enterasys Networks 8000/8600 User Manual

Page 77

background image

Enterasys X-Pedition 8000/8600 Getting Started Guide

65

Installing the Hardware

Installing the Control Module

The primary control module always resides in the CM slot. If you need to replace the primary
control module in the CM slot, or you want to install a redundant control module in slot CM/1, use
the following procedure (you will need a #2 Phillips screwdriver to perform this procedure). The
primary control module must be installed in slot CM. The redundant control module must be
installed in slot CM/1. (See Chassis

on page 10

for information about the chassis slots.)

Figure 30

shows an example of how to install a control module. The procedure following the figure

describes how to do this.

Figure 30. Installing a Control Module

To install the control module:

1.

If a coverplate is installed over the control module slot (slot or CM/1 only), use the #2 Phillips
screwdriver to remove it.

2.

Slide the control module all the way into the slot, firmly but gently pressing to ensure that the
pins on the back of the control module are completely seated in the backplane.

Note:

Make sure the circuit card (and not the metal plate) is between the card guides, as shown
in

Figure 30

. Check both the upper and lower tracks.

3.

Use the #2 Phillips screwdriver to tighten the captive screws on each side of the control module
to secure it to the chassis.

4.

When you are ready to attach the management cables to the control module, review the cable
specifications under SSR-CM2B-64, SSR-CM3-128, and SSR-CM4-256

on page 107

.

10/100 Mgmt

Console

SSR-8

SSR-CM2-64

CONTROL MODULE

Card Guides

Circuit Card

Metal Plate